About Widefield microscope
A widefield microscope is one type of Fluorescence Microscope .

In a conventional widefield microscope (WFM), the entire specimen is bathed in light from a mercury or xenon source, and the image can be viewed directly by eye or projected onto an image capture device or photographic film. When fluorescent specimens are imaged using such a microscope, secondary fluorescence emitted by the specimen that appears away from the region of interest often interferes with the resolution of those features that are in focus. This situation is especially problematic for specimens having a thickness greater than about 2 micrometers. ( source (external link)). Thus, such a microscope is not an intrinsic Three Dee Microscope .

Because of this lack of resolution, in widefield microscopes the Nyquist Rate is about double of that in confocal ones. See Confocal Microscope .

Example


This is a single XY (2D) slice of an original Multi Channel widefield stack :



Data courtesy of Dr. Rita Reis, Lab. Molecular Genetics, IBMC, Porto, Portugal.

This is the restored image slice, after deconvolving the whole stack using a QMLE algorithm as detailed in Deconvolution Procedure .



Restoring a 2D Wide Field Image


A widefield Point Spread Function (PSF) has the property that its plane-integrated intensity is constant. As a result the blur cone extending from objects is always truncated.

Truncated images can be handled by allowing the measured and object data space to be different, while computing the quality measure only over the measured region. In this way an object can be restored with larger extent than the measured region.

The ultimate consequence of this is the possibility to restore single-plane images.



Search the FAQ for "2D deconvolution".


Brightfield microscope


Brightfield microscopy is the simplest of all the optical microscopy illumination techniques. Sample illumination is transmitted (i.e., illuminated from below and observed from above) white light. The most common use of the microscope involves the use of a sample mounted to a glass microscope slide.(Source Wikipedia.org)

The Huygens Professional also includes the non-iterative Tikhanov Miller algorithm which proves to give excellent results combined with brightfield microscopes tuned and controlled using using a Shack-Hartmann? sensor.
See also the article of Dr. Oberlaender a.o. for more explanation.
See Huygens References .

 
Back to Browsing



 
Newsletter
Getting Updates, Special offers from our website
Follow us:
 ABOUT US

 PAYMENT & SHIPPING

 CUSTOMER SERVICE

 SECURITY & PRIVACY

 RESOURCES

 
Copyright © 2017 Microscopesmall.com All right reserved XML Sitemaps
 
Language Option:


Link: Microscopes, Dental loupes, Surgical headlight, Colposcope, Surgical microscopes, Microscopes parts, Stereo microscopes, Metallurgical microscopes, Flourescenc mcroscopes, window tint tools